PFE1100-12-054NA White Paper Issue 6
Energy Savings Using PFE1100-12-054NA
The following section details the energy effects using the PFE1100-12-054NA in a data center environment.
Table 5 detailed the server count for key companies. A rack of servers using 1100 W power supplies would
not be a typical x86 server; the power in these servers is more typically between 450 W to 850 W
This paper will demonstrate how much energy and carbon emissions are reduced in a single-rack
con?guration and a 10-rack con?guration, with both examples using the PFE power supply.
This example details systems requiring 1U redundant 1100 W front ends. The system power budget for this
example is set at 850 W maximum per server and the rack contains 40 x 1U servers.
Data center PUE for this example is set at 1.9, (de?ned as current trend by the EPA as shown in Table 4), with
the cost of electricity at 11 cents per kWh. Workload for each server has been set as a variable load
between 20% and 50% load of a single 1100 W supply, with the load shared 50:50 by the redundant PSU.
Power and climate comparison data is shown for each product across the Climate Saver speci?cations,
Silver, Gold, Platinum, and PFE1100-12-054NA. The baseline for all calculations is the Silver requirement as
de?ned in Table 6.
Table 6. Overview for power and climate example.
Power Supply Detail
Power Supplies In Rack (1100 W
each)
Servers in Rack
Number of Racks
Ef?ciency @20% Load Each PSU
Ef?ciency @50% Load Each PSU
Ef?ciency @100% Load Each PSU
Product Life (Years)
PUE
Design Load (PSU Capability)
Actual Power required based on load
Redundancy
Load
Electricity Cost ($/kWh)
CO2 kg/kWh (EPA Data Point)
P e r i t u s P o w e r !
80
40 x 1U
10
93.6%
94.7%
94.2%
5
1.5
System Rack Detail
34,000 W per rack
11,900 W per rack
Yes
Average (20-50%)
Environmental Data
$0.11
7.18 x 10-4 metric tons CO2 / kWh
P o w e r - O n e I N C . 1 U P F E 11 0 0 - 1 2 - 0 5 4 N A P l a t i n u m
11
相关PDF资料
PFE1100-12-054ND FRONT END 1100W 12V HI EFFICINCY
PFE500S-28/T PWR SUP AC/DC 85-265VAC 28V
PFE700S-48 PWR SUP AC-DC 85-265VAC 51V 14A
PFE850-12-054RA FRONT END 850W 12V HI EFFICIENCY
PGB1040805NR SUPPRESSOR ESD 24VDC 0805 SMD
PGB2010402KRHF SUPPRESSOR ESD 12VDC 0402 SMD
PHW603616 BOX FIBER 63.5X36.5X18.1" GREY
PI-1902 BOX ABS 1.26" X 1.97" X 3.54"GRY
相关代理商/技术参数
PFE1100-12-054ND 功能描述:FRONT END 1100W 12V HI EFFICINCY RoHS:是 类别:电源 - 外部/内部(非板载) >> AC DC 转换器 系列:* 产品培训模块:MP Modular-Configurable AC-DC Power Supply 特色产品:Configurable Power Supplies 标准包装:1 系列:MP
PFE1100-12-054RA 功能描述:FRONT END 1100W 12V HI EFFICINCY RoHS:是 类别:电源 - 外部/内部(非板载) >> AC DC 转换器 系列:* 产品培训模块:MP Modular-Configurable AC-DC Power Supply 特色产品:Configurable Power Supplies 标准包装:1 系列:MP
PFE1100-12-054RD 制造商:Power-One 功能描述:- Trays 制造商:Power-One 功能描述:Power One PFE1100-12-054RD DC to DC
PFE-12 制造商:FAIRFORD ELECTRONICS 功能描述:SOFTSTARTER PFE-12 22A 制造商:FAIRFORD ELECTRONICS 功能描述:SOFTSTARTER, PFE-12 22A 制造商:FAIRFORD ELECTRONICS 功能描述:SOFTSTARTER, PFE-12 22A; Supply Voltage Range:230V AC to 460V AC; No. of Phases:Three; Power Rating:15hp; Current Rating:22A; Operating Temperature Min:0C; Operating Temperature Max:40C; Approval Bodies:IEC; Control Voltage DC ;RoHS Compliant: NA
PFE12HSX-U 功能描述:线性和开关式电源 240W 12V 36A RoHS:否 制造商:TDK-Lambda 产品:Switching Supplies 开放式框架/封闭式:Enclosed 输出功率额定值:800 W 输入电压:85 VAC to 265 VAC 输出端数量:1 输出电压(通道 1):20 V 输出电流(通道 1):40 A 商用/医用: 输出电压(通道 2): 输出电流(通道 2): 安装风格:Rack 长度: 宽度: 高度:
PFE12HSX-U1 功能描述:线性和开关式电源 240W 12V 36A RoHS:否 制造商:TDK-Lambda 产品:Switching Supplies 开放式框架/封闭式:Enclosed 输出功率额定值:800 W 输入电压:85 VAC to 265 VAC 输出端数量:1 输出电压(通道 1):20 V 输出电流(通道 1):40 A 商用/医用: 输出电压(通道 2): 输出电流(通道 2): 安装风格:Rack 长度: 宽度: 高度:
PFE12HSX-U-P 功能描述:线性和开关式电源 240W 12V W/COVER RoHS:否 制造商:TDK-Lambda 产品:Switching Supplies 开放式框架/封闭式:Enclosed 输出功率额定值:800 W 输入电压:85 VAC to 265 VAC 输出端数量:1 输出电压(通道 1):20 V 输出电流(通道 1):40 A 商用/医用: 输出电压(通道 2): 输出电流(通道 2): 安装风格:Rack 长度: 宽度: 高度:
PFE1300-48-054NA 功能描述:POWER SUPPLY FRONT END 1.3KW FAN 制造商:bel power solutions 系列:PFE1300 零件状态:有效 类型:前端 输出数:1 电压 - 输入:90 ~ 264 VAC 电压 - 输出 1:48V 电压 - 输出 2:- 电压 - 输出 3:- 电压 - 输出 4:- 电流 - 输出(最大值):26.8A 功率(W):1300W 应用:ITE(商业) 电压 - 隔离:4.242kV(4242V) 效率:94% 工作温度:0°C ~ 45°C 特性:可调输出,热插拔,I2C? 接口,负载均分,PFC,PMBus?,远程开/关,遥测,待机输出 安装类型:机架安装 大小/尺寸:12.66" 长 x 2.15" 宽 x 1.57" 高(321.5mm x 54.5mm x 40.0mm) 所需最小负载:- 认可:CB,cCSAus,CE,NEMKO 功率(W) - 最大值:1286W 标准包装:30